Modell: KLW-UPS31-1KVA
Marke: Schlüssel-Lewatt
Garantiezeit: 3 Monate-1 Jahr
Herkunftsort: China
Phase: Drei Phasen
Schutz: Blitz, Kurzschluss, Überstrom, Unausgeglichene Lasten, Überspannung
Arten Von: Online
Geltungsbereich: Militär, Telekommunikation, MEDIZINISCH, Sicherheit / Überwachung / Alarm, Vernetzung, INSTRUMENTIERUNG
Input Voltage: 380V
Lieferfähigkeit & Zusatzinformationen
Transport: Ocean
HS-Code: 85044020
Zahlungsart: T/T
Incoterm: FOB,CIF,EXW,FCA
Produktbeschreibung
MP3100 -Serie Ununterbrochenes Netzteil
Niedrige Frequenz drei Phase in Einzelphasen-Online-UPS (6KVA-60KVA) Niedrigfrequenter Netzteil
MP3100 -Serie drei Phase in einer Phase Online -Ups Einführung
Online -UPS der MP3100 -Serie ist Online -Doppelkonvertierung mit niedriger Frequenz -UPS. Dieses Ups ist drei Phasen in einer Phase von 6 kVa bis 60 kVa. Die Eingangsspannung kann 380 VAC/400VAC/415 VAC oder optional 200 VAC/208 VAC/220 VAC als Bedarf von Clients betragen.
Diese Serie Online-UPS nimmt Hochgeschwindigkeitsmikroprozessor (MCU), programmierbares Logic Device (CPLD) -Programm an, das von der Software und dem Switch als Leistungskomponenten gesteuert wird. Dieses Serienprodukt kombiniert die weltweit neuesten Kontroll -Ersatzteile und die fortschrittlichste Software. Es ist so konzipiert, dass es hohe Verfügbarkeit und hohe Stromqualitätsbedürfnisse einer Vielzahl kritischer Anwendungen entspricht.
Wie bereits erwähnt, ist diese Art von Niederfrequenz-UPS-Anzug für die nichtlineare Last wie Klimaanlagen, Motoren, Drucker und ein anderes Produktionsfeld.
Online -UPS der MP3100 -Serie wird in Telekommunikation, Bank, Sicherheit, Transport, Versorgungsunternehmen, Manufaktur, Industrie, Handel, Regierung, medizinischer Geräte usw. häufig eingesetzt.
Haupteigenschaften
LED+LCD -Anzeige, erleichtern Sie den Vorgang über das LCD -Panel
Niedrige Frequenz echte Online-Doppelkonversionstechnologie
Erweiterte Digitalcir. -Systemdesign, erhöhen Sie die UPS -Stabilität
Erweiterte und intelligente Batterieverwaltung, verlängern Sie die Akkulaufzeit
Intelligentes Inspektionssystem, alle Arten von UPS -Arbeitsstatus inspizieren
SMD -Technik, Verbesserung der Zuverlässigkeit der Schaltung und laufende Präzision
IGBT -PWM -Wechselrichtertechnologie, die die Leistung von höchster Qualität liefern, ist die Effizienz höher auf 92%
Statischer Bypass -Betrieb, bieten Sie ein sicheres Versagen an den Netz
Manuelle Bypass -Betrieb, lassen Sie das technische Personal auf fehlerhaften Ups arbeiten und sicher, um die inneren Einheiten zu ändern.
256 Echtzeit -Ereignisprotokoll mit detaillierten Parametern
Standard RS232 & RS485, optionale Trockenkontakte oder SNMP -Karte zur Fernbedienung.
Ausgezeichnete Lastzeichen, Saltus von 0-100% erfüllen, ohne um zu umgehen, um zu umgehen, stabile Ausgabe schützen
Eingangs- und Ausgangsspannung, Batterieladung & Entladung, Temperatur, Kurzschluss und Überlast usw. Schutz
Unterschiedlicher Arbeitsmodus für Auswählungen: UPS, ECO oder Wechselrichterarbeitsmodus
Automatische Neustartfunktion
Perfekte Generatorkompatibilität
EPO & Surge -Schutz
Optionales Batterie -Erkennungsmodul
Optionale N+1 -Redundanz parallel, die Zuverlässigkeit des Systems erhöhen
Unterstützung mit Blei -Säure -Batterie und LifePO4 -Batterie -Leistungswandbatterie
Spezifikation:
Model |
MP3106kVA |
MP3110kVA |
MP3115kVA |
MP3120kVA |
MP3130kVA |
MP3140kVA |
MP3150kVA |
MP3160kVA |
MP3180kVA |
MP31100kVA |
MP31120kVA |
Nominal capacity (kVA/kW) |
6kVA/4.8kW |
10kVA/8KW |
15kVA/12kW |
20kVA/16kW |
30kVA/24kW |
40kVA/32kW |
50kVA/40kW |
60kVA/48kW |
80kVA/64kW |
100kVA/80kW |
120kVA/96kW |
Work principle |
Pure sine wave on line |
||||||||||
Phase |
3phase+N+G |
||||||||||
Rectifier |
|||||||||||
Nominal input voltage |
380vac/400vac/415vac or customized 200vac/208vac/220vac |
||||||||||
Voltage range |
±25% |
||||||||||
Nominal input frequency |
50Hz±10%, 60Hz±10% |
||||||||||
Output ripple |
<2% |
||||||||||
Soft start |
0~100% 5s |
||||||||||
Charge |
|||||||||||
Charge mode |
Constant current to constant voltage; with Auto change |
||||||||||
Float voltage |
216VDC |
405VDC |
|||||||||
Charge current |
0.1C( Automatically change follow the batteries ) |
||||||||||
Charge frequency |
20% of Rated capacity |
||||||||||
Battery |
|||||||||||
Battery type |
Maintenance-free lead acid battery |
||||||||||
Battery capacity |
7~999AH settable (according to the capacity) |
||||||||||
Battery number |
16pcs |
30pcs 12V,or 180pcs 2V(Nominal voltage 360VDC) |
|||||||||
Inverter |
|||||||||||
Phase |
Single L+N+G |
||||||||||
Output power factor |
0.8 |
||||||||||
Nominal voltage |
220VAC/230VAC/240VAC ( customized 100VAC/110VAC/120VAC) |
||||||||||
Output voltage stability |
±1%( Stable load), ±3%( fluctuant load) |
||||||||||
Output frequency stability |
50Hz/60Hz<±0. 5% |
||||||||||
Crest factor |
> 3:1 |
||||||||||
Output waveform distortion |
Sine wave, linear load<3%, non-linear load<5% |
||||||||||
Dynamic characteristics |
Instant voltage<±5%(from 0 to100% ), Instant recover time<10mS |
||||||||||
Unbalanced load voltage |
<±5% |
||||||||||
Overload protection |
115%10 min, 125%1min, 150%1s |
||||||||||
Efficiency |
>93%(full load) |
||||||||||
Bypass |
|||||||||||
Phase |
Single L+N |
||||||||||
Nominal voltage |
220VAC/230VAC/240VAC ( customized 100VAC/110VAC/120VAC) |
||||||||||
Transfer time |
<1mS ( static switch with 0 transfer time ) |
||||||||||
Protection |
|||||||||||
Input protection |
Input voltage/frequency over limited, wrong phase, lack phase |
||||||||||
Output protection |
Over current short circuit, factor low protection |
||||||||||
Battery protection |
Over charge, over-discharge protection |
||||||||||
Temperature protection |
Ambient over temperature protection, inverter over temperature protection |
||||||||||
Hardware failure protection |
Assistant power abnormal, breaker cut off , breaker overload, power components over current/over voltage etc protection |
||||||||||
System Parameters |
|||||||||||
Working environment |
Temp: 0~40℃, relative humidity 30%~90 %, ( a 1% decrease against 100 meters’ rise. Altitude 4000m MAX) |
||||||||||
Cooling –down method |
Compulsive ventilation (with temperature control) |
||||||||||
Communication Interface |
RS232, RS485, (optional SNMP card/ dry contact interface) |
||||||||||
Redundancy function |
In series or N+1 parallel |
||||||||||
Anti-surge capacity |
10/700μS, 5KA , 8/20μS, 20KA(Optional) |
||||||||||
Protection level |
IP31 |
IP20 |
|||||||||
Safety performance |
Vin-n Vout-n 3000Vac, creepage<3.5mA isolation resistance >3M(500VDC) |
||||||||||
Noise dB |
45~50 |
50~55 |
55~58 |
55~60 |
|||||||
Mechanical size (W×D×H)mm |
220×540×640 |
450×600×1200 |
600×720×1520 |
980×800×1800 |
|||||||
Net weight(Kg) |
65 |
168 |
186 |
210 |
246 |
338 |
338 |
420 |
570 |
640 |
720 |
Die obige Größe und das obige Gewicht dienen nur als Referenz, die tatsächliche Größe und das tatsächliche Gewicht hängen von den von Ihnen erhaltenen Waren ab . Alle angepassten UPS werden akzeptiert
The file is encrypted. Please fill in the following information to continue accessing it
heiße Produkte
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.